distributed power supply

Application field

Application field

Power supply application scenarios such as distributed data centers, load-bearing limited data centers, phased deployment of data centers, rapid deployment of data centers, and integrated cabinets.

 

Power range: 1KVA – 10KVA (1PH/1PH)

Main parameters

Technical parameter

Model

DPS-1103A

DPS-1106A

DPS-1110A

Capacity

3000VA / 2700W

6000VA / 5400W

 10000VA / 9000W

Input

Input voltage

220VAC

Voltage Range

176-250Vac @ (80-100%) load

Frequency Range

46Hz - 54Hz @ 50Hz system; 56Hz - 64Hz @ 60Hz system

Power Factor

0.99

Output

Output voltage

208/220/230/240VAC

Voltage accuracy

±1% (battery mode)

Frequency range

46Hz - 54Hz @ 50Hz system; 56Hz - 64Hz @ 60Hz system (Synchronization range)

Frequency range

50Hz±0.1Hz or 60Hz±0.1Hz(battery mode)

Power factor

0.9

Crest factor

3:1 Max.

Harmonic distortion

2% @ 100% linear load; 3% @ 100% non-linear load

Transfer time

0 ms (AC mode); 0 ms (Inverter Mode); 10 ms (Inverter ECO)

Run

Input and output

1 line input & 2 lines output or 2 lines input & 2 lines output

Efficiency

Inverter Mode

94%

Battery

Battery type

192/230V lithium battery

Battery capacity

10AH/12AH/15AH/18AH/20AH/25AH/30AH

Appearance

Dimension

D × W × H (mm)

800 ×438 ×88(2U) Power Host

800 ×438 ×176(4U)/264(6U) include the lithium battery

Net Weight (kg)

28 (power host)

Environment

Storage temperature

-25 - 55

Working temperature

0 - 45

Working altitude

2000 m

Working humidity

95% No condensation

Working noise

55dB @ 1 meter distance

Management

Intelligent slot

Support Window@2000/2003/XP/Vista/2008Window @7/8, Linux and MAC

Optional

Support SNMP CARD

  The output efficiency will be reduce to 60% when CVCF mode;

  The output power will be reduce to 90% when the output voltage set to 208VAC.

 

Technical parameter

Model

DPS-1101B

DPS-1102B

DPS-1103B

Capacity

1000VA / 800W

2000VA / 1600W

 3000VA / 2100W

Input

Input voltage

220VAC

Voltage Range

176-250Vac

Frequency Range

46Hz - 54Hz @ 50Hz system; 56Hz - 64Hz @ 60Hz system

Power Factor

0.99

Output

Output voltage

208/220/230/240VAC

Voltage accuracy

±1% (battery mode)

Frequency range

46Hz - 54Hz @ 50Hz system; 56Hz - 64Hz @ 60Hz system (Synchronization range)

Frequency range

50Hz±0.1Hz or 60Hz±0.1Hz(battery mode)

Power factor

0.8

0.7

Crest factor

3:1 Max.

Harmonic distortion

2% @ 100% linear load; 3% @ 100% non-linear load

Transfer time

6 ms (AC mode); 6 ms (Inverter Mode)

Run

Input and output

1 line input & 2 lines or 3 lines output

Efficiency

Inverter Mode

91% (30-100%) load

Battery

Battery type

48V lithium battery

Battery capacity

10AH/15AH/20AH

Appearance

Dimension

D × W × H (mm)

800 ×438 ×44(1U) Power Host

Net Weight (kg)

8 (power host)

Environment

Storage temperature

-25 - 55

Working temperature

0 - 45

Working altitude

2000 m

Working humidity

95% No condensation

Working noise

55dB @ 1 meter distance

Management

Intelligent slot

Support Window@2000/2003/XP/Vista/2008Window @7/8, Linux and MAC

Optional

Support SNMP CARD

  The product is subject to the actual product, and the above specifications are subject to change without notice;

  If the distributed power system is installed and used in an environment where the altitude exceeds 2000 meters, the output power should be calculated by 1% every 200 meters.

Features

Performance characteristics

  Intelligent detection, battery type optional, output shunt timing control

Intelligent detection of fan and capacitor running time

4 output shunts support timing control function

Battery type: lead-acid battery, lithium iron battery, ternary lithium battery and custom battery type

 

  Reliable, intelligent and fast deployment

Modular design, rapid deployment on demand;

Simplify data center planning and design;

Compatible with T2/T3/T4 level in the same data center;

Intelligent detection of running time of fans and capacitors;

Dual 220VAC input, dual 220VAC output, can intelligently detect the power of other equipment (optional).

 

  Effective use of space and load-bearing

The weight of the equipment is equivalent to that of the server, and the weight bearing only needs 500Kg/m2;

The deployment does not require independent distributed power system space and battery room, and the number of effective cabinets has increased by more than 40%;

 

Energy saving and emission reduction, cabinet-level energy management effectively combined with cloud computing

High efficiency power supply module, the efficiency of the whole series of products is as high as 94%;

Full lithium battery backup system, discharge efficiency up to more than 97%, life span up to 10 years;

Each output can be selected for time-sharing control. With the energy management system, it can achieve cabinet-level energy management and coordinate with cloud computing for scheduling;

 

Power supply host, modular design of lithium iron battery, hot swappable, easy installation and maintenance

The product is designed and produced in a modular manner. The power supply host and the iron-lithium battery are independent modules. They support hot swapping while ensuring that the power equipment does not lose power; small size, light weight, and can be completed by one person.

More convenient installation and simple maintenance

Reasonable design of heat dissipation and airflow control, good control of battery temperature;

The front part of the product is designed with heat dissipation holes and air ducts for the power supply heating device and the lithium battery, which can accurately control the temperature of the power supply and the lithium iron battery;

 

Conducive to the user’s demand for low "PUE" value

The distributed power supply mode divides the power consumption of the traditional large UPS into the cabinet and reduces the PUE value.

Data download