1.4M Power cabinet and 1.8M Power cabinet (Customizable)
Applications:
Telecommunication networks
Industrial facilities
Transportation infrastructure
Mobile telecommunication sites
Communication base stations
Remote sites, and outdoor events...
Item No :
ODC-P14/ODC-P18Order(MOQ) :
10 pcsPayment :
T/TProduct Origin :
ChinaColor :
RAL7035Shipping Port :
ShenzhenLead Time :
2 weeksWeight :
95-130 KgOutdoor power cabinet
Description
Outdoor Power Cabinet is mainly used in wireless communication base station, such as 5G system, communication/network integrated service, access/transmission switching station, emergency communication/transmission, etc. The cabinet can contain rectifier system, UPS, inverter, battery etc.
Features:
1. Reliability: Ensures continuous operation of telecommunication equipment by protecting it from environmental hazards.
2. Extended Equipment Lifespan: Enhances the longevity of electronic components by providing a protective environment.
3. Cost Savings: Reduces the need for frequent repairs and replacements, contributing to cost-effectiveness in network maintenance.
4. Network Expansion: Facilitates the expansion of telecommunication networks into outdoor and remote locations.
5. Secure Equipment: Prevents theft, vandalism, and unauthorized access to critical telecommunication infrastructure.
6. Efficient Maintenance: Easy accessibility and modular design simplify maintenance tasks, minimizing downtime.
7. Compliance with Standards: Cabinets are designed to comply with industry standards for safety, security, and environmental protection.
8. Adaptability: Adapts to various deployment scenarios, including urban, rural, and remote settings.
9. Remote Management: Enables remote monitoring and management, reducing the need for physical site visits.
10. Scalability: Scalable designs allow for the addition of equipment as network demands grow.
Advantages:
1. Functionality: CONSNANT Outdoor Telecom Cabinets are specifically designed to house and protect sensitive telecommunications equipment in outdoor environments. They provide a secure and controlled environment for equipment such as servers, switches, power supplies, and batteries, allowing for reliable and uninterrupted operation.
2. Materials: These cabinets are constructed using high-quality materials that are capable of withstanding harsh outdoor conditions. They are usually made of rugged and durable materials such as stainless steel, aluminum, or composite materials. These materials provide excellent resistance to corrosion, rust, extreme temperatures, and UV radiation.
3. Protection level: CONSNANT Outdoor Telecom Cabinets are built to provide a high degree of protection for the equipment housed inside. They typically have a high IP (Ingress Protection) rating, such as IP65 or IP66, which means they are effectively sealed against dust, water, and other environmental factors. This level of protection ensures the equipment remains safe and operable even in challenging weather conditions.
4. Security: These cabinets are equipped with robust locking mechanisms and security features to prevent unauthorized access and vandalism. They often include tamper-proof locks, alarm systems, and CCTV surveillance capabilities. This enhances the overall security of the telecom equipment and prevents unauthorized tampering or theft.
5. Thermal Management: CONSNANT Outdoor Telecom Cabinets are engineered with efficient thermal management systems to regulate the temperature inside the cabinet. They may feature cooling fans, heat exchangers, or air conditioning systems to dissipate heat generated by the equipment. This ensures optimal operating conditions and prevents overheating, which can lead to equipment failure.
6.Applications: CONSNANT Outdoor Telecom Cabinets find applications across a range of industries and settings, including telecommunication networks, industrial facilities, transportation infrastructure, remote sites, and outdoor events. They are essential for establishing reliable and secure communication networks in these diverse environments.
7. User Experience: CONSNANT Outdoor Telecom Cabinets are designed to provide a positive user experience. They often feature ergonomic designs, user-friendly interfaces, and easy equipment access for maintenance and servicing. Additionally, these cabinets may include remote monitoring capabilities, allowing operators to monitor equipment status and performance in real-time from a central location.
1.4M Power cabinet
Technical Parameters
Model | ODC-P14MX12A01 | ODC-P14AC15A01 |
Essential information | ||
Cabinet size | 800mm(W)*800mm(D)*1400mm(H) | |
Outside cabinet size | 905mm(W)*1080mm(D)*1705mm(H) | |
Floor space | 905mm(W)*905mm(D) | |
Substructure height | 200mm | |
Weight | 105kg (excluding equipment and battery) | 95kg (excluding the equipment and battery) |
User space | 31U | |
Frame material | SPCC - cold rolled steel (standard),Galvanized steel / Stainless Steel / Aluminium/Color Steel Sandwich Board (optional) | |
Wall plate material | Color steel sandwich plate: Color steel plate + polystyrene (polyurethane optional) | |
Wall plate thickness | 45mm | |
Gate lock | Heaven and earth three-point type anti-theft door lock, European standard lock core, can be replaced by themselves, can be equipped with the padlock | |
Levels of protection | IP55 | |
Bottom wire hole specification | 8*φ50 mm | |
Shipping form | Get ready to deliver | |
Cabinet storage temperature | -40℃~+70℃ | |
Relative humidity outside the cabinet | 5%~100% | |
Temperature control information | ||
Temperature control of equipment module | HX08 | PC1500 |
Power consumption | 70W | 600W @L35/L35 |
HX08 heat transfer coefficient / PC1500 cooling capacity | 80W/K | 1500W @L35/L35 |
Heater power consumption (optional) | 400W | 1000W |
Battery cabin temperature control | TC02 | / |
TC02 power consumption | Typical: 300W; maximum: 380W | / |
TC02 Refrigeration capacity | 200W | / |
Heater power consumption (optional) | 400W | / |
Battery information (optional) | ||
Battery specifications | 150-Ah 12V AGM battery | |
Battery capacity | 300Ah | |
Battery pack number | Group 2 | |
Other information | ||
Lighting (optional) | DC-48V LED lamp | |
Certification&Standards | ||
Product certification | With the TLC certification | |
Occupation standard | YD/T 1537-2015 |
1.8M Power cabinet
Model | ODC-P18AC15A01 | ODC-P18MX01A01 |
Essential information | ||
Cabinet size | 800mm(W)*800mm(D)*1800mm(H) | |
Outside cabinet size | 905mm(W)*1080mm(D)*2105mm(H) | |
Floor space | 905mm(W)*905mm(D) | |
Substructure height | 200mm | |
Weight | 125kg (excluding equipment and battery) | 130kg (excluding equipment and battery) |
User space | 40U | |
Frame material | SPCC - cold rolled steel (standard),Galvanized steel / Stainless Steel / Aluminium/Color Steel Sandwich Board (optional) | |
Wall plate material | Color steel sandwich plate: Color steel plate + polystyrene (polyurethane optional) | |
Wall plate thickness | 45mm | |
Gate lock | Heaven and earth three-point type anti-theft door lock, European standard lock core, can be replaced by themselves, can be equipped with the padlock | |
Levels of protection | IP55 | |
Bottom wire hole specification | 8*φ50mm | |
Shipping form | Get ready to deliver | |
Cabinet storage temperature | -40℃~+70℃ | |
Relative humidity outside the cabinet | 5%~100% | |
Temperature control information | ||
Temperature control of equipment module | PC1500 | HX08 |
Power consumption | 600W | 70W |
PC1500 Refrigeration capacity/HX08 Heat transfer coefficient | 1500W @L35/L35 | 80W/K |
Heater power consumption (optional) | 1000W | 400W |
Battery cabin temperature control | PC300 | TC02 |
The PC300 power consumption | 230W @L35/L35 | Typical: 300W; Maximum: 380W |
PC300 cooling capacity | 400W @L35/L35 | 200W |
Heater power consumption (optional) | 400W | 400W |
Battery information (optional) | ||
Battery specifications | 150-Ah 12V AGM battery | |
battery capacity | 300Ah | |
Battery pack number | Group 2 | |
Other information | ||
Lighting (optional) | DC-48V LED lamp | |
Certification & Standards | ||
Product certification | With the TLC certification | |
Occupation standard | YD/T 1537-2015 |
Tags :